GC-MS 3200 Gas chromatography mass spectrometry |
1.Basic parameters: 1.1 mass quantity range: 1.5 ~ 1024amu < br / > 1.2 detection limit: 1Pg octafluoronaphthalene < br / > 1.3 scanning speed: adjustable in the whole process, up to 10000amu / sec < br / > 1.4 ion source: standard configuration EI electron bombardment source, independent heating system 120 ~ 350 ℃ < br / > 1.5 detector: electronic multiplier with high voltage conversion stage |
2.Host configuration: Gas phase host: capillary split / non split injection system, fully automatic rear door opening, over temperature protection, ten step lift, Ms capillary connection and temperature control system< br /> Mass spectrometry host: ionization source, four-stage rod mass analyzer, high-voltage conversion electron multiplier, vacuum pump, turbomolecular pump, mass spectrometry tuning control unit, imported high and low vacuum meter < br / > All Chinese control system |
|
Data control software | MS 3200rt data acquisition and processing software |
Chromatographic column | Capillary column for mass spectrometry |
Brand computer | Founder, 2G, 500g, 19 inch LCD |
Brand printer | Brother, black and white laser printer |
Spare parts box | Spare parts and special tools |
Mass spectrometry system |
Mass number range:1.5~1024 amu Resolution: resolution per unit mass Sensitivity: EI source 1Pg octafluoronaphthalene s / N > 100:1 (full scan); PCI source 100PG benzophenone (BZP) s / N ≥ 100:1 (methane gas) Scanning speed: adjustable in the whole process, up to 10000U / S (digital scanning, step size 0.1U) Quality accuracy:±0.2u Quality stability:±0.10u/48h Ion source: electron bombardment source, inert anti pollution, ion source multi-point heating system to ensure the minimum temperature gradient in the working area of ion source, make the analysis state more stable, and reduce the directional fouling effect of pollutants caused by temperature blind spots; The unique alloy filament has a long service life, double filament; Independent heating system, accurate temperature control of 150 ~ 320 ℃, chemical ionization source and related interfaces can be provided according to customer requirements. Electronic energy: 5-150ev, program adjustable Emission current: 10-350 μ A program adjustable Quadrupole: metal molybdenum quadrupole mass analyzer (patent numbers 200710121744.9 and 200620134010.5) Detector: electron multiplier with - 10000v high energy dynode GC / MS interface: directly connected to capillary column, independent temperature control, 100 ~ 350 ℃ adjustable Front stage amplifier with automatic gain function High stability high voltage RF module It can be equipped with a direct injection rod for rapid qualitative analysis of solid or liquid samples Instrument auto / manual tuning The front stage pump adopts 180L / min mechanical pump, and the high vacuum adopts imported 250L / s turbomolecular pump The vacuum gauge is a cold cathode ionization vacuum gauge with detection range 1.0×10 -5 -1×10 2 Pa It has full scan (scan) and selective ion scan(SIM) Up to 128 groups can be selected for ion monitoring mode (SIM) The maximum time of full scan mode (scan) can reach 200Min Reasonable host structure design can not only save your space, but also facilitate internal maintenance and nursing For vacuum pump systems of different specifications, we can configure economical and reasonable vacuum pump combinations according to your actual analysis needs Ideal analytical sensitivity to meet most trace detection The optimized design structure of the analyzer can be easily upgraded to a chemical ionizer source without replacing too many parts. The standard quadrupole analyzer ensures the acquisition of accurate spectrum The invention discloses a quartz quadrupole device, an assembly method and an assembly feeler gauge thereof It has the function of vacuum leakage inspection Safety interlock function: pump power, shaft temperature, ion source temperature, transmission line temperature, column temperature box temperature, high voltage output module, filament and detector protection |
Chromatographic system |
The chromatography has an electronic flow control unit (EPC) Temperature heater of column box temperature control room5℃~400℃ The column box can be set with ten steps of programmed temperature rise Temperature control of injection port50℃~400℃ Split / non split injection port, fully automatic gas path system GC / MS capillary connection device Large screen LCD Full automatic rear door opening, overtemperature protection device, carrier gas pressure loss protection Temperature stability±0.03℃ Maximum running time:999.99min |
Data system |
Dedicated all Chinese Windows 98, Windows XP, Windows 2000, compatible with windows7 system platform The mass spectrometry workstation can be tuned automatically / manually Instrument fault remote diagnosis, vacuum fault instantaneous protection and electrical overload protection, etc The powerful processing ability can complete the qualitative and integral of the spectrum in a few seconds, and output a complete qualitative information report NIST, Wiley and other internationally recognized standard spectrum libraries are selected The convenient snap one button function makes the data conversion of data processing part and real-time acquisition part more convenient Diversified quantitative methods, including external standard method, internal standard method, normalization method, etc. tic, MC and Mic can be set arbitrarily to meet the quantitative requirements of different target spectra A variety of search programs are suitable for different analysis work contents The software is available in Chinese and English, ms3200rt GC-MS real-time analysis workstation and ms3200 mass spectrometer data processing system Built in oil analysis software toolkit |
Textile industry |
Textile testing, such as banned azo dyes, chlorophenol testing, etc |
Agricultural food safety |
Detect additives in food, plasticizers in food, pesticide residues, etc |
Flavor and fragrance industry |
Cosmetic testing, such as dioxane |
Electronic industry |
Such as detection of polybrominated biphenyls and polybrominated diphenyl ethers |
Environmental protection industry |
Analysis of organic pollutants in the environment (analysis of pollution in air, water quality and soil) |
Other industries |
For example, it is widely used in pharmaceutical industry, petrochemical industry and other fields |